Zum Hauptinhalt springen
ALUNOR RF
Sample · for illustration

This is what ships with your unit.

Every duplexer, combiner and multicoupler we ship comes with the document below — measured on the specific unit, traceable to its serial number. The sample on this page uses representative numbers from a VHF-DP-6-6 production run; your shipped report carries the actual readings of your actual unit.

ALUNOR RF
Per-unit factory sweep report
VHF-DP-6-6
6" 6-cavity VHF duplexer (BPBR) · 136–175 MHz
Serial
VHF-DP-6-6-2026-0428
Sweep date
2026-05-01

Methodology

Reference
VNA, 50 Ω, calibrated SOLT
Ambient
25 °C ±1 °C
Span / step
130–180 MHz · 25 kHz
Tx tuned to
162.412 MHz
Rx tuned to
167.412 MHz
Operator / station
Lab-3 · K. Aydın

Pass / fail summary

  • Tx-Rx isolation spec > 85 dB · measured 87.4 dB
  • Insertion loss (Tx) spec < 1.80 dB · measured 1.61 dB
  • Insertion loss (Rx) spec < 1.80 dB · measured 1.72 dB
  • Return loss (worst) spec > 18 dB · measured 21.3 dB
  • VSWR (worst) spec < 1.50 · measured 1.18

Measured response · S21

freq → MHz · vertical → dB
0 dB -25 -50 -75 130 140 150 160 170 180 Tx 162.412 MHz Rx 167.412 MHz M1: [email protected] = -87.4 dB M2: [email protected] = -86.5 dB IL Tx -1.61 dB IL Rx -1.72 dB

Trace files (S2P, Touchstone v1.0) included on the USB shipped with the unit.

Per-cavity tuning record

Cavity Role f0 (MHz) Q (loaded) Notch depth Tuning rod (turns)
C1 Tx pass 162.412 4 280 +3.2
C2 Tx pass 162.418 4 210 +3.0
C3 Tx notch 167.412 4 350 -26.3 +2.7
C4 Rx notch 162.412 4 330 -26.1 +2.6
C5 Rx pass 167.405 4 240 +3.1
C6 Rx pass 167.418 4 270 +3.0
Sign-off
All measurements in this report were taken on the unit with serial VHF-DP-6-6-2026-0428 on the date listed above. The unit ships with these results attached and a USB stick containing the raw S2P traces. If you re-tune the unit in the field, this report no longer reflects its current state — request a re-sweep.
K. Aydın
Test engineer · Lab-3
QC-stamp: PASS · 2026-05-01